Producción Científica Profesorado

Micro flow injection analysis of leucomalachite green in fish muscle using modified henequen fibers as microfluidic channels



Rodríguez Ávila, José Antonio

2021

T. Alexandra Ferreira, Alfredo Guevara-Lara,M. Elena Paez-Hernandez, Alicia C. Mondragon and Jose A. Rodriguez. Micro flow injection analysis of leucomalachite green in fish muscle using modified henequen fibers as microfluidic channels. RSC Adv., 2021,11, 35375-35382 https://doi.org/10.1039/D1RA06301D


Abstract


In this work a simple and novel procedure for leucomalachite green determination based on micro flow injection analysis (?FIA) with amperometric detection is presented. The method involves the use of henequen modified fibers as microfluidic channels. The ?FIA system proposed offers a simple, rapid, and low-cost alternative for the determination. Capillary and gravitational forces across the modified henequen fibers control the flow rate, eliminating the need for external pumps. This technique requires low reagent consumption and allows portability for in situ measurements. The flow system is described, and the operational variables were studied and optimized using a Taguchi parameters design to increase analytical sensitivity. Under optimal conditions a limit of detection of 1.16 ?g kg?1 was achieved with adequate repeatability and reproducibility (expressed as %RSD <5.0%, n = 3, n = 9 respectively) in all cases. The effect of interfering species and the accuracy of the method were also investigated. The proposed methodology was validated and applied to determine LMG in tilapia muscle samples.



Producto de Investigación




Artículos relacionados

Construction and Evaluation of a Gold Tubular Electrode for Flow Analysis: Application to Speciation...

Development of a Chloride Ion-Selective Solid State Sensor Based on Doped Polypyrrole-Graphite-Epoxy...

Potentiometric quantification of saccharin by using a selective membrane formed by pyrrole electropo...

Sequential Injection Spectrophotometric Determination of Diclofenac in Urine and Pharmaceutical Form...

Chemical studies of anthocyanins: A review

Development of a Chloride Ion-Selective Solid State Sensor Based on Doped Polypyrrole-Graphite-Epoxy...

Facilitated transport of Hg(II) through novel activated composite membranes

Determination of non-steroidal anti-inflammatory drugs in wastewaters by magnetic matrix solid phase...

Characterization of Main Anthocyanins Extracted from Pericarp Blue Corn by MALDI-ToF MS

Validation of a tubular bismuth film amperometric detector: Determination of diclofenac sodium by mu...