Producción Científica Profesorado

Electrochemical Determination of Pb(II) Using Carbon Paste Electrodes Modified with Ion Imprinted Polymers (IIPs).



Alvarez Romero, Giaan Arturo

2022

Luz E. Rebolledo, Giaan Arturo Álvarez Romero, Israel Samuel Ibarra-Ortega, Carlos Andres Galan-Vidal, Irma Pérez-Silva. (2022). Electrochemical Determination of Pb(II) Using Carbon Paste Electrodes Modified with Ion Imprinted Polymers (IIPs). ECS Transactions, 106, 21.


Abstract


An easy, low-cost, and highly selective carbon paste electrode based on an ion-imprinted polymer (IIP) to determine Pb(II) in real samples was developed. The recognition cavities based on a cross-linked polymer selective to Pb(II) were created using vinyl pyridine. The modified CPE was constructed by a composite mixture with the synthesized IIP. A notable difference was observed in the electrochemical response of the electrodes modified with the IIP and a non-imprinted polymer, demonstrating the unique properties of the IIP recognition sites. The parameters related to the current intensity were optimized; the selectivity was also studied considering potential interference ions. The proposed modified electrode demonstrated to be as (or more) selective to Pb(II) compared to others previously reported in the literature. A linear concentration range from 3.3 mg/L to 33 mg/L with a limit detection of 1 mg/L was obtained. The Pb(II) preconcentrated on the electrode surface was successfully quantified in real potable water samples without previous treatment.






Artículos relacionados

Potentiometric quantification of saccharin by using a selective membrane formed by pyrrole electropo...

Chemical studies of anthocyanins: A review

Renewable stationary phase liquid magnetochromatography: determining aspartame and its hydrolysis pr...

Simultaneous determination of tetracyclines in poultry muscle by capillary zone electrophoresis

Potentiometric Behavior of Diverse Polypyrrole-sulphate Films Electro Synthesized on Graphite - Epox...

Mercury Ions Removal from Aqueous Solution Using an Activated Composite Membrane

Determination of non-steroidal anti-inflammatory drugs in wastewaters by magnetic matrix solid phase...

Presence and antimicrobial resistance of Escherichia coli isolated from foodstuffs in Hidalgo State ...

Sequential Injection Spectrophotometric Determination of Diclofenac in Urine and Pharmaceutical Form...

Determination of glucose by flow injection analysis with amperometric detection at Fe(III)-(tris(3,5...