Producción Científica Profesorado

A Novel Voltammetric Approach For The Quantification of Aflatoxin B1 Using a Bismuth-Modified Electrode



Alvarez Romero, Giaan Arturo

2021

Aldahir A. Hernández-Hernández, Araceli Castañeda-Ovando, Luis H. Mendoza-Huizar, Miriam Franco-Guzmán, Karla X. Meneses-Pimentel, Carlos A. Galán Vidal, María E. Páez-Hernández, G. A. Álvarez Romero. A Novel Voltammetric Approach For The Quantification of Aflatoxin B1 Using a Bismuth-Modified Electrode. J. Electrochem. Soc. 2021, 168, 026512. DOI: 10.1149/1945-7111/abe349


Abstract


Aflatoxins are high-toxic secondary metabolites of Aspergillus fungus, which contaminate food at trace levels. Promising voltammetric methods were developed using mercury electrodes, however, they have negative effects on the environment. This work proposes the development and optimization of a differential pulse voltammetric methodology for the quantification of Aflatoxin B1 through bismuth film electrodes by the reduction of aflatoxin. Aflatoxin B1 reduction is controlled by its diffusion towards the electrode's surface. Optimal conditions for the preparation of the bismuth film and differential pulse voltammetry were obtained by Box-Behnken experimental designs, considering the maximization of the Aflatoxin B1 cathodic peak current. The LOD and LOQ resulted to be 11.2 ng l?1 and 37.3 ng l?1 respectively. The values for the reproducibility and repeatability as %RSD, using a 38.46 ng l?1 solution of Aflatoxin B1 for the measurements, were 5.3% and 4.6%, respectively. The proposed methodology was statistically validated using certified Aflatoxin B1 standard solutions and milk samples successfully analyzed, demonstrating that the proposed methodology represents a novel, low-cost, environmentally-friendly approach for the quantification of Aflatoxin B1.






Artículos relacionados

Potentiometric quantification of saccharin by using a selective membrane formed by pyrrole electropo...

Magnetic solids in analytical chemistry: A review

Construction and Evaluation of a Gold Tubular Electrode for Flow Analysis: Application to Speciation...

Determination of tetracyclines in milk samples by magnetic solid phase extraction flow injection ana...

Kinetics of Polypyrrole Films Doped with Sulphate Ions Electrodeposited Over Graphite - Epoxy Resin ...

Magnetic solid phase extraction based on phenyl silica adsorbent for the determination of tetracycli...

Mercury Ions Removal from Aqueous Solution Using an Activated Composite Membrane

Determination of glucose by flow injection analysis with amperometric detection at Fe(III)-(tris(3,5...

Potentiometric Behavior of Diverse Polypyrrole-sulphate Films Electro Synthesized on Graphite - Epox...

Determination of non-steroidal anti-inflammatory drugs in wastewaters by magnetic matrix solid phase...