Size exclusion chromatography (SEC-HPLC) as an alternative to study thrombin inhibition



Alvarez Romero, Giaan Arturo

2018

Size exclusion chromatography (SEC-HPLC) as an alternative to study thrombin inhibition, Pérez-Escalante, E., González-Olivares, L.G., Cruz-Guerrero, A.E., Galán-Vidal, C.A., Páez-Hernández, M.E., Álvarez-Romero, G.A., Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 1074-1075 (2018) 34-38, DOI: 10.1016/j.jchromb.2017.12.037


Abstract


In vitro analysis of anticoagulant compounds with a potential use as antithrombotic drugs, has been traditionally performed using techniques like spectrophotometry, turbidimetry, as well as electrochemical and clinical assays. Although, these techniques have some disadvantages such as: the inability to measure the total biological activity of thrombin, interferences and, sometimes, the quantitative determination of the inhibition ratio is not accurate. In the present work, the conversion of fibrinogen to fibrin was monitored by molecular exclusion chromatography (SEC-HPLC) in three different reaction systems. An inhibition percentage of 43.192.02% was obtained using heparin as an anticoagulant, in addition to the determination of the percentage of heparin bonded to thrombin. This methodology has not been previously described and has high potential for the determination of anticoagulant capacity with higher precision, the determination of thrombin's total biological activity and the quantitative determination of the inhibition ratio



Producto de Investigación




Artículos relacionados

Development of a Chloride Ion-Selective Solid State Sensor Based on Doped Polypyrrole-Graphite-Epoxy...

Simultaneous determination of tetracyclines in poultry muscle by capillary zone electrophoresis

Design and Construction of Solid State Ag/AgCl Reference Electrodes Through Electrochemical Depositi...

Influence of the Cation Nature of the Sulphate Salt on the Electrochemical Synthesis of Sulfate-Dope...

Silver and Silver Chloride Electrodeposits, an Alternative in the Construction of Ag/AgCl Solid Elec...

Metal content evaluation and its effect on the stability of anthocyanins

Determination of glucose by flow injection analysis with amperometric detection at Fe(III)-(tris(3,5...

Determination of primary amino acids in wines by high performance liquid magneto-chromatography

Determination of oxytetracycline in milk samples by polymer inclusion membrane separation coupled to...

Multicommutated Anodic Stripping Voltammetry at Tubular Bismuth Film Electrode for Lead Determinatio...