Producción Científica Profesorado

New insights on diclofenac electrochemistry using graphite as working electrode



Rodríguez Ávila, José Antonio

2017

G.Y. Aguilar-Lira, G.A. Álvarez-Romero, A. Zamora-Suárez, M. Palomar-Pardavé, A. Rojas-Hernández, J.A. Rodríguez-Ávila, M.E. Páez-Hernández. New insights on diclofenac electrochemistry using graphite as working electrode. Journal of Electroanalytical Chemistry 794 (2017) 182-188. doi:10.1016/j.jelechem.2017.03.050


Abstract


This paper reports new investigation on the electrochemical behavior of diclofenac using a bare graphite electrode. The electrochemical oxidation of diclofenac was studied using cyclic voltammetry (CV), an anodic peak was found at 0.557 V as reported earlier by other authors, reversing the cycle results in a new cathodic peak at 0.272 V, which is proposed to be related with the reduction of 2-(2hydroxyprop-2-enyl) acetic acid. During the second cycle a new cathodic peak is observed at 0.333 V, associated to the oxidation of 2-(2hydroxyprop-2-enyl) acetic acid to 1-hydroxy-2-(hydroxyphenyl) ethanalate. Both electrochemical processes resulted to be adsorption-controlled, statistical fit of theoretical information with the experimental voltammograms, one electron transference is demonstrated which supports the proposed mechanism. From an analytical point of view, it was demonstrated that direct quantification of diclofenac using the anodic oxidation peak results less favorable when compared with an indirect quantification using the 2-(2hydroxyprop-2-enyl) acetic acid oxidation peak. The modified Simplex method was used to optimize differential pulse voltammetry parameters to achieve an exact and precise quantification of diclofenac in standard and real samples obtaining very competitive results compared with other more sophisticated working electrodes.



Producto de Investigación




Artículos relacionados

Multicommutated Anodic Stripping Voltammetry at Tubular Bismuth Film Electrode for Lead Determinatio...

Potentiometric Behavior of Diverse Polypyrrolesulphate Films Electro Synthesized on Graphite Epoxy ...

Development of a Polypyrrole Selective Membrane For The Potentiometric Quantification of Saccharinat...

Metal content evaluation and its effect on the stability of anthocyanins

Determination of oxytetracycline in milk samples by polymer inclusion membrane separation coupled to...

Development of a Chloride Ion-Selective Solid State Sensor Based on Doped Polypyrrole-Graphite-Epoxy...

Synthesis, characterization, and crystal structures of n-alkyldiorganodithiophosphates RS2P(OC6H4)2

Silver and Silver Chloride Electrodeposits, an Alternative in the Construction of Ag/AgCl Solid Elec...

Chemical studies of anthocyanins: A review

Determination of tetracyclines in milk samples by magnetic solid phase extraction flow injection ana...