Producción Científica Profesorado

Sequential Injection Magneto Chromatography Determination of Non-Steroidal Anti-Inflammatory Drugs in Pharmaceutical Formulations.



Ibarra Ortega, Israel S.

2013

I.S. Ibarra, J.A. Rodríguez, K. Aguilar-Arteaga, E. Contreras-Lopez, Enrique Barrado. Sequential Injection Magneto Chromatography Determination of Non-Steroidal Anti-Inflammatory Drugs in Pharmaceutical Formulations. Analytical Letters, 46 (2013) 1732-1742DOI: 10.1080/00032719.2012.755685


Abstract


A magnetic separation method based on the use of magnetic silica as the stationary phase in sequential injection chromatography was used for simultaneous determination of nonsteroidal anti-inflammatory drugs (acetaminophen, naproxen, diclofenac, and ibuprofen) in tablets. The method is based on a thin layer paramagnetic stationary phase retained on the inner wall of a mini-column through the action of an external magnetic field. The influence of the variables involved was evaluated and the optimal conditions were found to be: a methyl-silica magnetic adsorbent was used as the stationary phase, the mobile phase was methanol-water (60:40, v/v), pH 2.5 adjusted with 98% phosphoric acid, a flow rate 0.60 ml min?1, and UV detection at 225 nm. Under these conditions, the linear range of the calibration curve ranged from 3?6 mg L?1 to 100 mg L?1 with limits of detection ranging between 1 to 2 mg L?1. The proposed method was validated by comparing the results obtained against those provided by high performance liquid chromatography; no significant differences were seen



Producto de Investigación




Artículos relacionados

Multicommutated Anodic Stripping Voltammetry at Tubular Bismuth Film Electrode for Lead Determinatio...

Development of a novel composite sensor based on doped pyrrole selective to nitrate ions

Silver and Silver Chloride Electrodeposits, an Alternative in the Construction of Ag/AgCl Solid Elec...

Metal content evaluation and its effect on the stability of anthocyanins

Evaluación del contenido de metales y su efecto en la estabilidad de antocianinas

Development of a Chloride Ion-Selective Solid State Sensor Based on Doped Polypyrrole-Graphite-Epoxy...

Development of a Chloride Ion-Selective Solid State Sensor Based on Doped Polypyrrole-Graphite-Epoxy...

High-performance liquid magneto-chromatography

Determination of tetracyclines in milk samples by magnetic solid phase extraction flow injection ana...

Kinetics of Polypyrrole Films Doped with Sulphate Ions Electrodeposited Over Graphite - Epoxy Resin ...