Producción Científica Profesorado

Sequential Injection Magneto Chromatography Determination of Non-Steroidal Anti-Inflammatory Drugs in Pharmaceutical Formulations.



Ibarra Ortega, Israel S.

2013

I.S. Ibarra, J.A. Rodríguez, K. Aguilar-Arteaga, E. Contreras-Lopez, Enrique Barrado. Sequential Injection Magneto Chromatography Determination of Non-Steroidal Anti-Inflammatory Drugs in Pharmaceutical Formulations. Analytical Letters, 46 (2013) 1732-1742DOI: 10.1080/00032719.2012.755685


Abstract


A magnetic separation method based on the use of magnetic silica as the stationary phase in sequential injection chromatography was used for simultaneous determination of nonsteroidal anti-inflammatory drugs (acetaminophen, naproxen, diclofenac, and ibuprofen) in tablets. The method is based on a thin layer paramagnetic stationary phase retained on the inner wall of a mini-column through the action of an external magnetic field. The influence of the variables involved was evaluated and the optimal conditions were found to be: a methyl-silica magnetic adsorbent was used as the stationary phase, the mobile phase was methanol-water (60:40, v/v), pH 2.5 adjusted with 98% phosphoric acid, a flow rate 0.60 ml min?1, and UV detection at 225 nm. Under these conditions, the linear range of the calibration curve ranged from 3?6 mg L?1 to 100 mg L?1 with limits of detection ranging between 1 to 2 mg L?1. The proposed method was validated by comparing the results obtained against those provided by high performance liquid chromatography; no significant differences were seen



Producto de Investigación




Artículos relacionados

Design and Construction of Solid State Ag/AgCl Reference Electrodes Through Electrochemical Depositi...

Mercury Ions Removal from Aqueous Solution Using an Activated Composite Membrane

Potentiometric quantification of saccharin by using a selective membrane formed by pyrrole electropo...

Development of a novel nitrate-selective composite sensor based on doped polypyrrole

Estudio de las Interacciones Ácido Húmico-Metales Pesados y Determinación de sus Constantes de Estab...

Construction and Evaluation of a Gold Tubular Electrode for Flow Analysis: Application to Speciation...

Potentiometric quantification of saccharin by using a selective membrane formed by pyrrole electropo...

Potentiometric Behavior of Diverse Polypyrrolesulphate Films Electro Synthesized on Graphite Epoxy ...

Prevalence and Antimicrobial Resistance Patterns of Salmonella from Different Raw Foods in Mexico

Potentiometric Behavior of Diverse Polypyrrole-sulphate Films Electro Synthesized on Graphite - Epox...