Producción Científica Profesorado

Potentiometric quantification of thebenzoate ion in nonalcoholic beveragesusing a solid electrode modified with apolypyrrole-based selective membrane



Páez Hernández, María Elena

2013

Potentiometric quantification of thebenzoate ion in nonalcoholic beveragesusing a solid electrode modified with apolypyrrole-based selective membraneAguilarLira G.Y., AlvarezRomero G.A.,deJ.LiconaSanchez T., PaezHernandezM.E., GalanVidal C.A., RomeroRomoM.A.(2013) Electroanalysis 25 1519-1527 10.1002/elan.2013000


Abstract


This work presents the results obtained on the construction of a potentiometric ion-selective electrode based on a polypyrrole (PPy) selective membrane to quantify the benzoate ion in nonalcoholic beverages. The electrode modification with benzoate (Benz?1) ion doped-Ppy was carried out under an imposed potential, while the electrosynthesis optimization was undertaken using the modified Simplex method, such that the film?s sensitivity was maximized toward the benzoate ion. The maximum sensitivity recorded was ?52.021.55?mV/decade [Benz?1] using a graphite powder-araldite resin composite electrode. During the modified electrode?s characterization it was found out that the response and drift were relatively short, namely 2?min and 0.4?mV?min?1 respectively, within the 7 to 9 pH range, exhibiting a detection limit of 7×10?4?mol?L?1 and a quantification range of 3×10?3 at 10?1?mol?L?1. Selectivity coefficients were evaluated with the Matched Potential Method obtaining in all cases values much less than 1. The benzoate concentration in commercially available juices and sweetened beverages was evaluated comparing the results obtained with the proposed ion-selective electrode and those of HPLC, the usually accepted technique. A statistical analysis of the results led to the conclusion that there exists no meaningful difference between the results obtained with both techniques, which shows the usefulness of the ion-selective electrode to proceed with the quantification in real samples.



Producto de Investigación




Artículos relacionados

Simultaneous determination of tetracyclines in poultry muscle by capillary zone electrophoresis

Magnetic solids in analytical chemistry: A review

Development of a Polypyrrole Selective Membrane For The Potentiometric Quantification of Saccharinat...

Design and Construction of Solid State Ag/AgCl Reference Electrodes Through Electrochemical Depositi...

Evaluación del contenido de metales y su efecto en la estabilidad de antocianinas

Characterization of Main Anthocyanins Extracted from Pericarp Blue Corn by MALDI-ToF MS

Development of a Chloride Ion-Selective Solid State Sensor Based on Doped Polypyrrole-Graphite-Epoxy...

Facilitated transport of Hg(II) through novel activated composite membranes

Determination of primary amino acids in wines by high performance liquid magneto-chromatography

Sequential Injection Spectrophotometric Determination of Diclofenac in Urine and Pharmaceutical Form...