Abstract


A selective electrode for the quantification of saccharinate ion based on a polypyrrole-doped membrane is developed. The membrane is electrochemically prepared using stainless steel as working electrode. Potentiostatic variables for membrane growing such as pyrrole concentration, saccharinate concentration, applied potential and deposition time are optimized in order to maximize sensibility. The optimized membrane was analytically characterized by means of calibration curves, the detection limit was found to be 3.6 x 10-4 M and the quantification limits were found between 5 x 10-4 M and over 1 M. Selectivity of the membrane is evaluated for different inorganic anions, resulting in the following selectivity coefficients: pKSaccharinate,Citrate= 3.4, pKSaccharinate,H2PO4= 3.4, pKSaccharinate,HPO4-2= 3.4 y pKSaccharinate,SO4-2= 2.5. This results demonstrate an adecuate performance of the proposed selective polypyrrole membrane so it can be considered as an alternative to the tradicional analytical methods for the direct quantification of sacarine in diverse samples.



Producto de Investigación




Artículos relacionados

Development of a Chloride Ion-Selective Solid State Sensor Based on Doped Polypyrrole-Graphite-Epoxy...

Electrochemical and AFM characterization of the electropolimerization of pyrrole over a graphiteepox...

Facilitated transport of Hg(II) through novel activated composite membranes

Sequential Injection Spectrophotometric Determination of Diclofenac in Urine and Pharmaceutical Form...

Determination of tetracyclines in milk samples by magnetic solid phase extraction flow injection ana...

Potentiometric Behavior of Diverse Polypyrrolesulphate Films Electro Synthesized on Graphite Epoxy ...

Determination of glucose by flow injection analysis with amperometric detection at Fe(III)-(tris(3,5...

Metal content evaluation and its effect on the stability of anthocyanins

Renewable stationary phase liquid magnetochromatography: determining aspartame and its hydrolysis pr...

Determination of non-steroidal anti-inflammatory drugs in wastewaters by magnetic matrix solid phase...