Producción Científica Profesorado

Determination of glucose by flow injection analysis with amperometric detection at Fe(III)-(tris(3,5-dimethyl-1-pyrazolyl)borate)2 modified electrodes



Rodríguez Ávila, José Antonio

2011

Hernandez, P., Rodriguez, J.A., Salazar, V., Álvarez-Romero, G.A., González-Montiel, S., Castrillejo Y. Determination of glucose by flow injection analysis with amperometric detection at Fe(III)-(tris(3,5-dimethyl-1-pyrazolyl)borate)2 modified electrodes, Journal of the Mexican Chemical Society, 2011, Vol. 55, p. 120-125, ISSN 1870-249X


Abstract


A modified screen printed electrode with [Fe(tris(3,5-dimethyl-1-pyrazolyl)borate)2] + [FeCl4]-, installed as part of a flow injection system, was used as an amperometric detector to determine hydrogen peroxide and glucose after on-line reaction with glucose oxidase. The influence of experimental variables on sensitivity, such asthe flow rate, injection volume and reaction coil length, was evaluatedusing a two-level factorial experimental design. Under optimal conditions, detection limits of 15 M and 0.5 mM for H2O2 and glucose, respectively, were obtained. A sampling rate of 60 determinations h-1 was achieved; the relative standard deviation of analytical measurements was <5.0%. The method was validated by comparing the obtained results with those provided by the enzymatic spectrophotometric method; no significant differences were observed (p < 0.05). Keywords: Glucose, Hydrogen peroxide, Flow injection system.



Producto de Investigación




Artículos relacionados

Potentiometric Behavior of Diverse Polypyrrolesulphate Films Electro Synthesized on Graphite Epoxy ...

Potentiometric quantification of saccharin by using a selective membrane formed by pyrrole electropo...

Magnetic solid phase extraction based on phenyl silica adsorbent for the determination of tetracycli...

Determination of tetracyclines in milk samples by magnetic solid phase extraction flow injection ana...

Development of a Chloride Ion-Selective Solid State Sensor Based on Doped Polypyrrole-Graphite-Epoxy...

Potentiometric behavior of graphite-epoxy electrochemical transducers towards anions, cations and pH...

Development of a Polypyrrole Selective Membrane For The Potentiometric Quantification of Saccharinat...

cis-Palladium(II) complexes of derivatives of di-(2-pyridyl)methane: Study of the influence of the b...

Kinetics of Polypyrrole Films Doped with Sulphate Ions Electrodeposited Over Graphite - Epoxy Resin ...

Potentiometric quantification of saccharin by using a selective membrane formed by pyrrole electropo...