Producción Científica Profesorado

Magnetic solid phase extraction based on phenyl silica adsorbent for the determination of tetracyclines in milk samples by capillary electrophoresis



Rodríguez Ávila, José Antonio

2011

Ibarra, I.S., Rodriguez, J.A., Miranda, J.M., Vega, M., Barrado, E. Magnetic solid phase extraction based on phenyl silica adsorbent for the determination of tetracyclines in milk samples by capillary electrophoresis, Journal of Chromatography A, 2011, Vol. 1218, p. 2196-2202, ISSN 0021-9673


Abstract


A magnetic solid phase extraction method coupled to capillary electrophoresis is proposed for the determination of tetracycline, oxytetracycline, chlortetracycline and doxycycline in milk samples. Five different magnetic phenyl silica adsorbents covered with magnetite were synthesized by varying the molar ratio of phenyltrimethylsilane and tetramethylorthosilicate; these adsorbents were evaluated in terms of their pH and degree of hydrophobicity for tetracycline retention. The optimal, selected combination of conditions was a pH of 10.0 and a magnetic sorbent ratio of 4:1; under these conditions, the retention capacity ranged from 99.7% to 101.2% for the four tetracyclines analyzed. The elution conditions and initial sample volume of the proposed extraction method were also optimized, and the best results were obtained with 1 × 10?3 M acetic acid in methanol as eluent and a 200 ml of sample volume. Under optimal conditions, average recoveries ranged from 94.2% to 99.8% and the limits of detection ranged from 2 to 9 ?g l?1 for the four tetracyclines. After the proposed method was optimized and validated, 25 milk samples of different brands were analyzed, oxytetracycline residues were detected in five samples, in concentrations ranging from 98 to 213 ?g l?1. Subsequent analysis of positive samples by SPECE and magnetic solid phase extractionHPLC revealed than no significant differences were found from results obtained by the proposed methodology. Thus, the developed magnetic extraction is a robust pre-concentration technique that can be coupled to other analytical methods for the quantitative determination of tetracyclines.



Producto de Investigación




Artículos relacionados

Nucleation and Growth Kinetics of Electrodeposited Sulfate-Doped Polypyrrole: Determination of the D...

Determination of glucose by flow injection analysis with amperometric detection at Fe(III)-(tris(3,5...

Presence and antimicrobial resistance of Escherichia coli isolated from foodstuffs in Hidalgo State ...

Magnetic solids in analytical chemistry: A review

Development of a Chloride Ion-Selective Solid State Sensor Based on Doped Polypyrrole-Graphite-Epoxy...

Synthesis and crystal structures of cis-palladium(II) and cis-platinum(II) complexes containing dipy...

Potentiometric Behavior of Diverse Polypyrrole-sulphate Films Electro Synthesized on Graphite - Epox...

Determination of tetracyclines in milk samples by magnetic solid phase extraction flow injection ana...

Potentiometric Behavior of Diverse Polypyrrolesulphate Films Electro Synthesized on Graphite Epoxy ...

Design and Construction of Solid State Ag/AgCl Reference Electrodes Through Electrochemical Depositi...