Producción Científica Profesorado

Validation of a tubular bismuth film amperometric detector: Determination of diclofenac sodium by multisyringe flow injection analysis



Rodríguez Ávila, José Antonio

2007

Rodriguez, J.A, Barrado, E., Castrillejo, Y., Santos, J.R., Lima, J.L.F.C. Validation of a tubular bismuth film amperometric detector. Determination of diclofenac by multisyringe flow injection analysis, Journal of Pharmaceutical and Biomedical Analysis, 2007, Vol. 45, p. 47-53, ISSN: 0731-7085


Abstract


A tubular bismuth film electrode (BFE), installed as part of a multisyringe flow injection system, was used as an amperometric detector to determine the concentration of diclofenac sodium in pharmaceutical formulations. A tubular voltammetric detection cell was employed, in which the hydrodynamic flow conditions were not disturbed. This automated method allows the continuous regeneration of the BFE, preventing passivation of the detector and improving the sensitivity of detection. The influence of several variables on this sensitivity, such as the injection volume, deposition time and flow rate were evaluated; a two-level factorial experimental design was employed for this. In optimal conditions, the linear range of the calibration curve varied from 6.050.0 ?mol L?1, with a detection limit of 4.3 ?mol L?1. A sampling rate of 90 determinations/h was achieved; the relative standard deviation of analytical repeatability was <3.5%. After 30 injections the bismuth film on the electrode surface was automatically renewed. The method was validated by comparing the results obtained with those provided by RP-HPLC; no significant difference were seen (p < 0.05).



Producto de Investigación




Artículos relacionados

Development of a Polypyrrole Selective Membrane For The Potentiometric Quantification of Saccharinat...

Magnetic solids in analytical chemistry: A review

Presence and antimicrobial resistance of Escherichia coli isolated from foodstuffs in Hidalgo State ...

Sequential Injection Spectrophotometric Determination of Diclofenac in Urine and Pharmaceutical Form...

Potentiometric Behavior of Diverse Polypyrrolesulphate Films Electro Synthesized on Graphite Epoxy ...

Determination of glucose by flow injection analysis with amperometric detection at Fe(III)-(tris(3,5...

Construction and Evaluation of a Gold Tubular Electrode for Flow Analysis: Application to Speciation...

Characterization of Main Anthocyanins Extracted from Pericarp Blue Corn by MALDI-ToF MS

Renewable stationary phase liquid magnetochromatography: determining aspartame and its hydrolysis pr...

Design and Construction of Solid State Ag/AgCl Reference Electrodes Through Electrochemical Depositi...