Producción Científica Profesorado

Validation of a tubular bismuth film amperometric detector: Determination of diclofenac sodium by multisyringe flow injection analysis



Rodríguez Ávila, José Antonio

2007

Rodriguez, J.A, Barrado, E., Castrillejo, Y., Santos, J.R., Lima, J.L.F.C. Validation of a tubular bismuth film amperometric detector. Determination of diclofenac by multisyringe flow injection analysis, Journal of Pharmaceutical and Biomedical Analysis, 2007, Vol. 45, p. 47-53, ISSN: 0731-7085


Abstract


A tubular bismuth film electrode (BFE), installed as part of a multisyringe flow injection system, was used as an amperometric detector to determine the concentration of diclofenac sodium in pharmaceutical formulations. A tubular voltammetric detection cell was employed, in which the hydrodynamic flow conditions were not disturbed. This automated method allows the continuous regeneration of the BFE, preventing passivation of the detector and improving the sensitivity of detection. The influence of several variables on this sensitivity, such as the injection volume, deposition time and flow rate were evaluated; a two-level factorial experimental design was employed for this. In optimal conditions, the linear range of the calibration curve varied from 6.050.0 ?mol L?1, with a detection limit of 4.3 ?mol L?1. A sampling rate of 90 determinations/h was achieved; the relative standard deviation of analytical repeatability was <3.5%. After 30 injections the bismuth film on the electrode surface was automatically renewed. The method was validated by comparing the results obtained with those provided by RP-HPLC; no significant difference were seen (p < 0.05).



Producto de Investigación




Artículos relacionados

Determination of primary amino acids in wines by high performance liquid magneto-chromatography

Potentiometric quantification of saccharin by using a selective membrane formed by pyrrole electropo...

Determination of tetracyclines in milk samples by magnetic solid phase extraction flow injection ana...

Determination of non-steroidal anti-inflammatory drugs in wastewaters by magnetic matrix solid phase...

Development of a novel nitrate-selective composite sensor based on doped polypyrrole

Development of a Chloride Ion-Selective Solid State Sensor Based on Doped Polypyrrole-Graphite-Epoxy...

Mercury Ions Removal from Aqueous Solution Using an Activated Composite Membrane

Evaluación del contenido de metales y su efecto en la estabilidad de antocianinas

Design and Construction of Solid State Ag/AgCl Reference Electrodes Through Electrochemical Depositi...

cis-Palladium(II) complexes of derivatives of di-(2-pyridyl)methane: Study of the influence of the b...